Skip navigation View an alternate layout of this website with limited styles and no horizontal scrolling
Menu

Design enhancement of a solid ankle-foot orthosis: real-time contact pressures evaluation

By Nowak, Michael D., ScD Abu-Hasaballah, Khamis S., PhD; Cooper, Paul S., MD; Journal of Rehabilitation Research and Development, Vol. 37, No. 3
Publication Date: May/June 2000

The purpose of our study was to evaluate all contact pressures between the molded ankle-foot orthosis (MAFO) and the subject during activities of daily living. The MAFOs studied are used clinically to reduce plantar contact pressures associated with foot ulcers in adult neuropathic diabetic subjects, alleviating abnormal pressures by redistributing them to low-pressure plantar regions. While effective, MAFOs are often not used by the subject due to weight and comfort issues. An understanding of the contact pressures between the subject and the orthosis is a first step in improving basic MAFO design. Four nonimpaired, young adult males were tested in this study. A right-side MAFO was custom-molded and fitted for each subject by the same orthotist. Real-time pressures were obtained for the entire contact area using the F-Scan pressure measurement system. The data obtained demonstrated high contact pressures along the metatarsals of the foot, around the heel and ankle, and adjacent to the strap attachment sites. No contact pressures were noted along the posterior calf region during any of the activities performed. These data suggest the calf region would be a suitable site for material removal for weight reduction and increased comfort, especially in warm weather. In addition, these data may be useful to orthotists in improving the basic design and to researchers as a starting point for performing complex finite element analysis on the MAFO.
Published by:
VA Rehabilitation Research & Development Service    (Web Site: http://www.rehab.research.va.gov )
Link to text: http://www.vard.org/jour/00/37/3/nowak373.htm

AbleData, 8630 Fenton Street, Suite 930, Silver Spring, MD 20910. 1-800-227-0216.
Maintained for the National Institute on Disability and Rehabilitation Research of the U.S. Dept. of Education
by ICF Macro under Contract No. ED-04-CO-0018/0007.

The records in AbleData are provided for information purposes only. Neither the U.S. Department of Education nor ICF Macro has examined, reviewed, or tested any product, device, or information contained in AbleData. The Department and ICF Macro make no endorsement, representation, or warranty express or implied as to any product, device, or information set forth in AbleData. The views expressed on this site do not necessarily represent the opinions of the Department of Education, the National Institute on Disability and Rehabilitation Research, or ICF Macro.