  1. BIOMUSE Picture of BIOMUSE BioMuse is a cursor control interface designed for use by individuals with severe physical or neurological disabilites or spinal cord or brain injury. This bioelectric signal controller is a rack-mountable package that enables users to control computer functions directly from muscle or eye movement or brainwave signals, bypassing standard input hardware, such as a keyboard or mouse. This device receives data from four main sources of electrical activity in the human body: muscles (EMG signals), ...[More Information]

  2. Computer Interface For Optical Headpointer. ------- "DO IT YOURSELF" ENTRY ------- PURPOSE: Optical headpointer and photodetector circuit designed to be immune to false triggering. Describes a photodetector circuit tuned to respond only to light pulsed at 90 Hertz (from a headpointer beam), ignoring shifts in ambient light level and room lighting. Circuit output feeds directly into a computer. Includes circuit diagrams for a lamp driver and a photodetector. COMMENTS: For further information contact: G L Heseltine, Science Unlimited Resear...[More Information]

  3. LIGHT BEAM INDICATOR Light Beam Indicator is a head-mounted pointing system using both a pointing rod and an adjustable padded nylon headset with a light pointer. The rod, which attaches to the nylon headset, projects out over the forehead and downward. The light pointer is positioned over the forehead and projects a concentrated light beam. Contact manufacturer for information on system options. POWER: Three "C" batteries. DIMENSIONS: 22 inches long. WEIGHT: 11.5 ounces....[More Information]

  4. LIGHT BEAM INDICATOR (MODEL 1) Light beam indicator for an alternative pointing method. For individuals with limited neck, trunk mobility or positioning control. On/off switch, rechargeable power pack....[More Information]

  5. LIGHT BEAM INDICATOR (MODEL 2) Lightweight flexible plastic headwand with washable forehead felt pad, cushioned chin strap and Velcro elastic band closure. Focused light beam indicator is mounted over forehead. Provides alternative pointing method for individuals with limited neck, trunk mobility or control when used with positioning. Weight 3.5 ounces. Light beam indicator has on, off switch adaptable to individual needs. Rechargeable power pack....[More Information]

  6. LIGHT POINTER The Light Pointer is an optical pointer designed for use by individuals with physical disabilities. This device projects a spot of light and is designed to be mounted on the user's head and pointed toward objects. The Light Pointer can also be used to activate the Light Activated Switch (see separate entry from this manufacturer)....[More Information]

  7. LIGHT POINTER WITH HEADSTICK (MODEL II) Model II Light Pointer with Headstick is a head-mounted pointing system using both a pointing rod and a light beam. An adjustable padded nylon headset holds the mountings for both the rod and the light pointer. The rod projects out over the forehead and downward. The light pointer is positioned over the forehead and projects a concentrated light beam. The light beam is visible under normal room lighting. POWER: Three "C" batteries. DIMENSIONS: 22 inches long. WEIGHT: 11.5 ounces....[More Information]

  8. REDLITE Optical pointer produces a focused red target pattern on a wall or any object within three feet of the user. Consists of pointer assembly 3 1/ 2 inches long and 5/8 inch in diameter, elastic handband for mounting the light, and battery pack and cable. Weighs less than a single AA battery. Operates for over 200 hours on two C alkaline cells. Mounts on a cap or on a pair of glasses. PVC construction with solid state optical element....[More Information]

  9. SAFE-LASER SYSTEM (MODEL SLS-100) Picture of SAFE-LASER SYSTEM (MODEL SLS-100) The Safe-laser System, model SLS-100, is an optical pointer and keyboard designed for use by individuals with severe physical or neurological disabilities, stroke, or spinal cord injury. The system includes the Safe-laser Keyboard, the uPoint safe-laser, a headband for wearing the laser, USB and audio cables, configuration software, and a charger. The specialized keyboard enables a person to access a computer through head movement when the laser is worn on the head. The laser can also allow the ...[More Information]

  10. VACUUM WAND Picture of VACUUM WAND The Vacuum Wand is a mouthstick designed for use by individuals with upper extremity disabilities, spinal cord injury, and severe physical disabilities. Made of aluminum and plastic, this device is designed for turning book or magazine pages. Features include a suction cup tip and two interchangeable ends that can be cut to the desired length. DIMENSIONS: The shaft is 18 inches long....[More Information]

Page 1 of 1

View discontinued Products (15)

AbleData, 8630 Fenton Street, Suite 930, Silver Spring, MD 20910. 1-800-227-0216.
Maintained for the National Institute on Disability and Rehabilitation Research of the U.S. Dept. of Education
by ICF Macro under Contract No. ED-04-CO-0018/0007.

The records in AbleData are provided for information purposes only. Neither the U.S. Department of Education nor ICF Macro has examined, reviewed, or tested any product, device, or information contained in AbleData. The Department and ICF Macro make no endorsement, representation, or warranty express or implied as to any product, device, or information set forth in AbleData. The views expressed on this site do not necessarily represent the opinions of the Department of Education, the National Institute on Disability and Rehabilitation Research, or ICF Macro.